+90 530 493 30 01 info@znr.com.tr TürkçeEnglish Online Payment
Dealer login
Home  /  Solutions  /  Waterproofing  /  Foundations and retaining walls
Waterproofing

Foundation and retaining wall waterproofing

On buried retaining walls and foundation surfaces, water arrives from the positive side — the face the pressure comes from. If the waterproofing is not applied to that face, water travels inside the concrete, corrodes the reinforcement and shows up indoors as damp.

01 — System

Layers

5 layers, in application order.

LayerProductRoleConsumption and packaging
01 Surface repair ZNR REPAIR C5
303
On segregation, blowholes and damaged surfaces. When required. 2.00 kg/m² for 1 mm thickness
25 kg kraft bag
02 Plugging an active leak ZNR WP PLUG
106
If water is running, it is stopped before the waterproofing. When required. Varies depending on the condition of the substrate
5 kg and 20 kg plastic buckets
03 Primer ZNR P 200
201
Evens out absorbency and increases adhesion. Mandatory. 0.100–0.175 kg/m² (Varies depending on surface conditions)
5 kg and 30 kg plastic jerry cans
04 Waterproofing ZNR WP 2K
101
Two coats, crosswise. 2 mm in total. Mandatory. 1.90 kg/m² for 1 mm thickness (Varies depending on surface conditions)
25 kg Set (A: Liquid 5 kg – B: Powder 20 kg)
05 Drainage and protection Drenaj levhası
not a ZNR product
Protects the waterproofing from mechanical damage during backfilling. Equal to the area
Roll

Consumption and packaging are read from the product record and are not written separately on this page — when the product is updated, this is updated too.

02 — Products

ZNR products used in this system

4 products. The other items in the system (insulation board, dowel, drainage board, mechanical work) are not ZNR products and are not in the catalogue.

03 — From the field

Frequently asked questions

Can waterproofing be applied from the negative side?

It is done when the building is already standing and there is no other option, but it does not replace positive-side waterproofing. Water keeps travelling inside the concrete and the reinforcement is not protected.

Can the primer be skipped?

It should not be. On absorbent concrete, waterproofing mortar applied without a primer loses its water to the substrate, cannot set and adhesion drops.

Why two thin coats instead of one thick one?

A single thick coat cracks at the surface and the continuity of the film is lost. Applied in two crosswise coats, the risk of pinholes disappears as well.

Can waterproofing be applied directly while water is running?

No. Running water washes the mortar out. The leak is stopped first with a plugging mortar, then the waterproofing is applied.

Let’s discuss the detail on site

Details such as the parapet return, the drain mouth and the expansion joint decide the fate of the system. Our technical team looks at it in place.

Request technical support