On buried retaining walls and foundation surfaces, water arrives from the positive side — the face the pressure comes from. If the waterproofing is not applied to that face, water travels inside the concrete, corrodes the reinforcement and shows up indoors as damp.
5 layers, in application order.
| Layer | Product | Role | Consumption and packaging | |
|---|---|---|---|---|
| 01 | Surface repair |
ZNR REPAIR C5
303
|
On segregation, blowholes and damaged surfaces. When required. |
2.00 kg/m² for 1 mm thickness
25 kg kraft bag
|
| 02 | Plugging an active leak |
ZNR WP PLUG
106
|
If water is running, it is stopped before the waterproofing. When required. |
Varies depending on the condition of the substrate
5 kg and 20 kg plastic buckets
|
| 03 | Primer |
ZNR P 200
201
|
Evens out absorbency and increases adhesion. Mandatory. |
0.100–0.175 kg/m²
(Varies depending on surface conditions)
5 kg and 30 kg plastic jerry cans
|
| 04 | Waterproofing |
ZNR WP 2K
101
|
Two coats, crosswise. 2 mm in total. Mandatory. |
1.90 kg/m² for 1 mm thickness
(Varies depending on surface conditions)
25 kg Set (A: Liquid 5 kg – B: Powder 20 kg)
|
| 05 | Drainage and protection |
Drenaj levhası
not a ZNR product
|
Protects the waterproofing from mechanical damage during backfilling. |
Equal to the area
Roll
|
Consumption and packaging are read from the product record and are not written separately on this page — when the product is updated, this is updated too.
4 products. The other items in the system (insulation board, dowel, drainage board, mechanical work) are not ZNR products and are not in the catalogue.

Cement-Based Two-Component Flexible Waterproofing Material

Plugging Mortar

General-Purpose Acrylic Primer

Shrinkage-Free Cement-Based Structural Fine Repair Mortar
It is done when the building is already standing and there is no other option, but it does not replace positive-side waterproofing. Water keeps travelling inside the concrete and the reinforcement is not protected.
It should not be. On absorbent concrete, waterproofing mortar applied without a primer loses its water to the substrate, cannot set and adhesion drops.
A single thick coat cracks at the surface and the continuity of the film is lost. Applied in two crosswise coats, the risk of pinholes disappears as well.
No. Running water washes the mortar out. The leak is stopped first with a plugging mortar, then the waterproofing is applied.
Details such as the parapet return, the drain mouth and the expansion joint decide the fate of the system. Our technical team looks at it in place.