+90 530 493 30 01 info@znr.com.tr TürkçeEnglish Online Payment
Dealer login
Home  /  Solutions  /  Industrial Flooring  /  Car park floor coating
Industrial Flooring

Car park floor coating

What finishes a car park floor is not the load but the kind of load. Tyre marks, the lateral force of braking and turning, drops of fuel and antifreeze, salt water carried in during winter — concrete on its own stands up to none of these. The surface dusts, the coating lifts, water reaches the reinforcement.

Which one is your job?
01 — System

Enclosed car park

4 layers, in application order.

LayerProductRoleConsumption and packaging
01 Surface preparation and repair ZNR REPAIR C5
303
Blowholes, cracks and level differences after shot blasting. When required. 2.00 kg/m² for 1 mm thickness
25 kg kraft bag
02 Primer ZNR PRIMER EP
407
Fills the pores and establishes the adhesion of the body coat. Mandatory. If surface moisture is above 4%, use 405 ZNR 501 C. 150–300 g/m² (Varies depending on surface conditions)
20 kg Set (A: 14 kg + B: 6 kg)
03 Body coat ZNR SELF LEVELING FLORING EP-2K
410
Self-leveling epoxy, 2 mm. The layer that carries the load and provides the seal. Mandatory.
⚠ a site–TDS difference for consumption is awaiting a decision
1.20–1.40 kg/m² for 1 mm thickness (Varies depending on surface conditions)
20 kg Set (A: 16 kg + B: 4 kg)
04 Anti-slip surface Kuvars kumu serpme
not a ZNR product
On ramps, turning areas and pedestrian routes. Broadcast while the body coat is still wet. 0.5-1.5 kg/m²
25 kg bag

Consumption and packaging are read from the product record and are not written separately on this page — when the product is updated, this is updated too.

02 — Products

ZNR products used in this system

4 products. The other items in the system (insulation board, dowel, drainage board, mechanical work) are not ZNR products and are not in the catalogue.

03 — From the field

Frequently asked questions

Can the primer be applied without measuring surface moisture?

It should not be. If the moisture content of the concrete is above 4% by weight, a standard epoxy primer will not hold and the coating blisters within a few months. In that case the moisture-tolerant 405 ZNR 501 C is used.

Is acid washing enough instead of blasting?

It is not. Acid does not remove the laitance completely and leaves salts on the surface. An open-pored surface must be obtained by shot blasting or grinding; adhesion depends on it.

Is the system on ramps the same as on flat floors?

No. On ramps and turning areas braking and lateral forces are high; a broadcast anti-slip quartz is mandatory and consumption comes out close to the upper limit.

Is a UV topcoat needed in an enclosed car park?

It is not. On a surface that never sees the sun an aliphatic topcoat is an added cost. However, where the entrance ramp and the open edges receive daylight, it is applied to those areas.

Let’s discuss the detail on site

Details such as the parapet return, the drain mouth and the expansion joint decide the fate of the system. Our technical team looks at it in place.

Request technical support