In a bathroom water does not pond, it seeps. Tiles and grout are assumed to be watertight; in fact the grout is absorbent and the void under the tile holds the water. If the waterproofing is not beneath the tile, the water shows up on the wall of the next room or on the ceiling of the floor below.
7 layers, in application order.
| Layer | Product | Role | Consumption and packaging | |
|---|---|---|---|---|
| 01 | Surface repair and falls |
ZNR REPAIR C5
303
|
Level differences and the fall to the drain. The floor must fall at least 1% towards the drain. |
2.00 kg/m² for 1 mm thickness
25 kg kraft bag
|
| 02 | Plugging an active leak |
ZNR WP PLUG
106
|
If water is running from a pipe penetration or the foot of a drain, it is stopped first. When required. |
Varies depending on the condition of the substrate
5 kg and 20 kg plastic buckets
|
| 03 | Primer |
ZNR P 200
201
|
Mandatory on absorbent screed and render. Stops the waterproofing mortar losing its water. |
0.100–0.175 kg/m²
(Varies depending on surface conditions)
5 kg and 30 kg plastic jerry cans
|
| 04 | Corner and drain tape |
Katalogda ürün kaydı yok
not a ZNR product
|
Wall-to-floor corners, drain collars and pipe penetrations. Embedded into the first coat of the waterproofing. A mandatory part of the system. |
Running length of junctions
—
|
| 05 | Waterproofing |
ZNR WP 2K SE
103
|
Cement-based fully flexible. Preferred in permanently wet conditions and where there is thermal movement. Mandatory. |
1.70 kg/m² for 1 mm thickness
(Varies depending on surface conditions)
30 kg Set (A: Liquid 10 kg – B: Powder 20 kg)
|
| 06 | Tile adhesive |
ZNR TILEBOND 5000 ULTRAFLEX
704
|
Class C2TES2. On permanently wet surfaces and those subject to thermal movement.
⚠ a site–TDS difference for class is awaiting a decision |
3.0–7.0 kg/m²
(Varies depending on substrate condition)
C2TES2 Class Adhesive Mortar
25 kg kraft bag
|
| 07 | Grout |
ZNR EPOFUGA
711
|
Epoxy based. Does not absorb water, resists chemicals and mould. Mandatory in areas requiring hygiene. |
Varies depending on substrate and joint dimensions
5 kg set
(A + B)
|
Consumption and packaging are read from the product record and are not written separately on this page — when the product is updated, this is updated too.
9 products. The other items in the system (insulation board, dowel, drainage board, mechanical work) are not ZNR products and are not in the catalogue.

Cement-Based Two-Component Flexible Waterproofing Material

Cement-Based Fully Flexible Waterproofing Material

Plugging Mortar

General-Purpose Acrylic Primer

Shrinkage-Free Cement-Based Structural Fine Repair Mortar

Flexible Ceramic and Granite Adhesive

Flexible Tile Adhesive

Epoxy-Based Grout and Adhesive

Ceramic and Wall Tile Grout
They are not. Cement-based grout is absorbent and the void under the tile collects water. Tiling is a finish, not a waterproofing layer; the waterproofing must always be beneath the tile.
At least 180 cm in the shower area; 30 cm above floor level is enough on other walls. In permanently wet commercial areas it is taken up to the ceiling. The splash zone should not be underestimated.
It cannot. The wall-to-floor junction is the point of the structure that moves most, and the waterproofing becomes discontinuous there. The tape separates the movement from the waterproofing film.
Cement-based waterproofing must be allowed to cure fully; fixing early both reduces adhesion and traps moisture beneath the waterproofing. Follow the waiting time on the product’s technical data sheet.
Details such as the parapet return, the drain mouth and the expansion joint decide the fate of the system. Our technical team looks at it in place.