In a bathroom water does not pond, it seeps. Tiles and grout are assumed to be watertight; in fact the grout is absorbent and the void under the tile holds the water. If the waterproofing is not beneath the tile, the water shows up on the wall of the next room or on the ceiling of the floor below.

Which one is your job?
01 — System

Hammam, spa, commercial kitchen

7 layers, in application order.

LayerProductRoleConsumption and packaging
01 Surface repair and falls ZNR REPAIR C5
303
Level differences and the fall to the drain. The floor must fall at least 1% towards the drain. 2.00 kg/m² for 1 mm thickness
25 kg kraft bag
02 Plugging an active leak ZNR WP PLUG
106
If water is running from a pipe penetration or the foot of a drain, it is stopped first. When required. Varies depending on the condition of the substrate
5 kg and 20 kg plastic buckets
03 Primer ZNR P 200
201
Mandatory on absorbent screed and render. Stops the waterproofing mortar losing its water. 0.100–0.175 kg/m² (Varies depending on surface conditions)
5 kg and 30 kg plastic jerry cans
04 Corner and drain tape Katalogda ürün kaydı yok
not a ZNR product
Wall-to-floor corners, drain collars and pipe penetrations. Embedded into the first coat of the waterproofing. A mandatory part of the system. Running length of junctions
—
05 Waterproofing ZNR WP 2K SE
103
Cement-based fully flexible. Preferred in permanently wet conditions and where there is thermal movement. Mandatory. 1.70 kg/m² for 1 mm thickness (Varies depending on surface conditions)
30 kg Set (A: Liquid 10 kg – B: Powder 20 kg)
06 Tile adhesive ZNR TILEBOND 5000 ULTRAFLEX
704
Class C2TES2. On permanently wet surfaces and those subject to thermal movement.
⚠ a site–TDS difference for class is awaiting a decision
3.0–7.0 kg/m² (Varies depending on substrate condition) C2TES2 Class Adhesive Mortar
25 kg kraft bag
07 Grout ZNR EPOFUGA
711
Epoxy based. Does not absorb water, resists chemicals and mould. Mandatory in areas requiring hygiene. Varies depending on substrate and joint dimensions
5 kg set (A + B)

Consumption and packaging are read from the product record and are not written separately on this page — when the product is updated, this is updated too.

02 — Products

ZNR products used in this system

9 products. The other items in the system (insulation board, dowel, drainage board, mechanical work) are not ZNR products and are not in the catalogue.

03 — From the field

Frequently asked questions

Aren’t tiles and grout watertight anyway?

They are not. Cement-based grout is absorbent and the void under the tile collects water. Tiling is a finish, not a waterproofing layer; the waterproofing must always be beneath the tile.

How far up the wall should the waterproofing go?

At least 180 cm in the shower area; 30 cm above floor level is enough on other walls. In permanently wet commercial areas it is taken up to the ceiling. The splash zone should not be underestimated.

Can it be done without corner tape?

It cannot. The wall-to-floor junction is the point of the structure that moves most, and the waterproofing becomes discontinuous there. The tape separates the movement from the waterproofing film.

How long after waterproofing can tiles be fixed?

Cement-based waterproofing must be allowed to cure fully; fixing early both reduces adhesion and traps moisture beneath the waterproofing. Follow the waiting time on the product’s technical data sheet.

Let’s discuss the detail on site

Details such as the parapet return, the drain mouth and the expansion joint decide the fate of the system. Our technical team looks at it in place.

Request technical support