What finishes a terrace is not the rain but the water staying there. On a terrace with a bad fall, water ponds, lifts the coating through freeze-thaw cycles and finds its way in through the smallest discontinuity. The problem usually does not start in the middle of the surface; it starts at the foot of the parapet, around the drain and at the expansion joint.

Which one is your job?
01 — System

Terrace to be left exposed

4 layers, in application order.

LayerProductRoleConsumption and packaging
01 Falls and surface repair ZNR REPAIR C5
303
Ponding areas, cracks and cove returns. The fall must be at least 2%. 2.00 kg/m² for 1 mm thickness
25 kg kraft bag
02 Primer ZNR WP 130 PX
109
Solvent-borne polyurethane primer. Seals the pores and establishes the adhesion of the membrane. Mandatory. 0.150–0.250 kg/m² (Varies depending on surface conditions)
20 kg Set (A: 17.35 kg – B: 2.65 kg)
03 Waterproofing membrane ZNR WP 180
111
Solvent-free polyurethane, 2 coats crosswise, 2 mm in total. Seamless and flexible. Mandatory.
⚠ a site–TDS difference for mixing ratio, consumption is awaiting a decision
1.40 kg/m² for 1 mm thickness
20 kg Set (A: 17 kg – B: 3 kg)
04 UV-protective topcoat ZNR PUWA TOPCOAT
416
Water-based polyurethane, 2 coats. Protects the membrane from UV yellowing. Mandatory on exposed terraces.
⚠ a site–TDS difference for consumption is awaiting a decision
0.100–0.160 kg per coat (Varies depending on surface conditions)
10 kg Set (A: 8.2 kg + B: 1.8 kg)

Consumption and packaging are read from the product record and are not written separately on this page — when the product is updated, this is updated too.

02 — Products

ZNR products used in this system

8 products. The other items in the system (insulation board, dowel, drainage board, mechanical work) are not ZNR products and are not in the catalogue.

03 — From the field

Frequently asked questions

Is waterproofing enough without a fall?

It is not. Waterproofing stops the water but does not prevent ponding. Standing water lifts the coating through freeze-thaw cycles and finds the smallest discontinuity. The fall must be at least 2%; otherwise a screed to falls is laid first.

Can a corner be turned without a cove?

It should not be. At a sharp 90-degree corner where the wall meets the slab the membrane is stretched and tears in time. A concave cove is formed at the corner with repair mortar and the waterproofing is carried over it.

Can it be applied over an old bituminous membrane?

Not directly. Polyurethane is incompatible with bitumen, and the bitumen can soften and migrate. The old membrane is removed, or a separating layer and a suitable primer are used — this situation should be put to the technical team.

Isn’t a single thick coat faster?

Faster but wrong. A single thick coat skins over on the surface, does not cure underneath and blisters. Two coats are applied crosswise; the second closes the pinholes of the first.

Let’s discuss the detail on site