Applicators
The layer order of every system and the application temperature of the products are on this page. The application note and consumption of each layer are in the table on the system page.
Layer order
Layers are in application order. 01 is the layer next to the substrate; the highest number is the final coat.
Foundation and retaining wall waterproofing
Foundation and retaining wall waterproofing
- 01Surface repairZNR REPAIR C5 303
- 02Plugging an active leakZNR WP PLUG 106
- 03PrimerZNR P 200 201
- 04WaterproofingZNR WP 2K 101
- 05Drainage and protectionDrenaj levhası
Terrace and roof waterproofing
Terrace to be left exposed
- 01Falls and surface repairZNR REPAIR C5 303
- 02PrimerZNR WP 130 PX 109
- 03Waterproofing membraneZNR WP 180 111
- 04UV-protective topcoatZNR PUWA TOPCOAT 416
Terrace to be tiled
- 01Falls and surface repairZNR REPAIR C5 303
- 02PrimerZNR P 200 201
- 03WaterproofingZNR WP 2K SE 103
- 04Tile adhesiveZNR TILEBOND 5000 ULTRAFLEX 704
- 05GroutZNR FUGA FLEX 1200 712
Wet area waterproofing
Domestic bathroom and kitchen
- 01Surface repair and fallsZNR REPAIR C5 303
- 02Plugging an active leakZNR WP PLUG 106
- 03PrimerZNR P 200 201
- 04Corner and drain tapeNo catalogue product
- 05WaterproofingZNR WP 2K 101
- 06Tile adhesiveZNR TILEBOND FLEX 701
- 07GroutZNR FUGA FLEX 1200 712
Hammam, spa, commercial kitchen
- 01Surface repair and fallsZNR REPAIR C5 303
- 02Plugging an active leakZNR WP PLUG 106
- 03PrimerZNR P 200 201
- 04Corner and drain tapeNo catalogue product
- 05WaterproofingZNR WP 2K SE 103
- 06Tile adhesiveZNR TILEBOND 5000 ULTRAFLEX 704
- 07GroutZNR EPOFUGA 711
Concrete repair and strengthening
Surface repair
- 01Removing damaged concreteMekanik işlem
- 02Bonding primerZNR REPAIR AC 306
- 03Fine repair mortarZNR REPAIR C5 303
- 04CuringZNR CURE 100 600
Structural repair
- 01Removing damaged concrete and cleaning the reinforcementMekanik işlem
- 02Reinforcement corrosion protectionZNR ANTICOROSIVE SFZ 420
- 03Bonding primerZNR REPAIR AC 306
- 04Structural repair mortarZNR REPAIR CS 45 305
- 05CuringZNR CURE 100 600
Anchoring and void filling
- 01Cleaning out the voidMekanik işlem
- 02Formwork and sealingMekanik işlem
- 03Free-flowing groutZNR GROUT C60 300
- 04CuringZNR CURE 100 600
Car park floor coating
Enclosed car park
- 01Surface preparation and repairZNR REPAIR C5 303
- 02PrimerZNR PRIMER EP 407
- 03Body coatZNR SELF LEVELING FLORING EP-2K 410
- 04Anti-slip surfaceKuvars kumu serpme
Open or top-deck car park
- 01Surface preparation and repairZNR REPAIR C5 303
- 02PrimerZNR PRIMER EP 407
- 03Body coatZNR SELF LEVELING FLORING EP-2K 410
- 04UV-resistant topcoatZNR PUSO 650 XH 417
Decorative flooring
Stamped concrete
- 01Dry-shake hardenerZNR BASKI BETON YS 607
- 02Release agentZNR RA 608
- 03WashingYüzey temizleyici
- 04Polish and protectionZNR V 120 609
Power-trowelled hardened floor
- 01Dry-shake hardenerZNR T200 605
- 02CuringZNR CURE 100 600
Protecting the existing surface
- 01Water-repellent impregnationZNR SIGUARD 610
- Alternative, solvent basedZNR SOGUARD 611
Facade thermal insulation, external insulation
New build
- 01Surface preparationToz alma ve yüzey düzeltme
- 02PrimerZNR P 200 201
- 03Board adhesiveZNR POLIBOND 500
- 04Insulation boardEPS, XPS veya taşyünü
- 05Mechanical fixing, anchorsIsı yalıtım dübeli
- 06Render and reinforcing meshZNR POLIPLAST 501
- 07PrimerZNR P 200 201
- 08Decorative renderZNR POLIDECOR 502
Refurbishment of an existing building
- 01Surface preparationEski boya raspası ve aderans testi
- 02PrimerZNR P 200 201
- 03Board adhesiveZNR POLIBOND 500
- 04Insulation boardEPS, XPS veya taşyünü
- 05Mechanical fixing, anchorsIsı yalıtım dübeli
- 06Render and reinforcing meshZNR POLIPLAST 501
- 07PrimerZNR P 200 201
- 08Decorative renderZNR POLIDECOR 502
Products with a consumption calculator
On the pages of 87 products you can enter the area and see the total material and the number of packs. For the other 25 products, ask technical support for quantities.
- Waterproofing 12 products
- ZNR WP 1C 100
- ZNR WP 2K 101
- ZNR WP 2K SE 103
- ZNR WP 2K UV 104
- ZNR WP CRYSTAL 105
- ZNR WP LP 107
- ZNR WP 2000 108
- ZNR WP 130 PX 109
- ZNR WP 150 110
- ZNR WP 180 111
- ZNR WP POLYUREA 112
- ZNR WP COALTAR EPOXY 113
- Repair, grout and restoration 14 products
- ZNR GROUT C60 300
- ZNR GROUT C60 R 301
- ZNR GROUT C70 302
- ZNR REPAIR C5 303
- ZNR REPAIR C30 304
- ZNR REPAIR CS 45 305
- ZNR REPAIR AC 306
- ZNR FIX EP 300T 307
- ZNR PUTTY EP 308
- ZNR PUTTY EP WT 309
- EPOBOND 311
- ZNR PUR A 50 312
- ZNR GROUT EP 420 W 313
- ZNR READY MIX 314
- Industrial and decorative coating 22 products
- ZNR PRIMER EW 400
- ZNR EP 1500 402
- ZNR P 400 403
- ZNR P 500 404
- ZNR 501 C 405
- ZNR P 600 406
- ZNR PRIMER EP 407
- ZNR COATING EP 408
- ZNR WP 100 DW 409
- ZNR SELF LEVELING FLORING EP-2K 410
- PRIMER VEEP 413
- ZNR VEEP 1500 414
- ZNR JEELCOAT VEEP 415
- ZNR PUWA TOPCOAT 416
- ZNR PUSO 650 XH 417
- ZNR GLOSS COAT 418
- ZNR COURT PAINT 419
- ZNR ANTICOROSIVE SFZ 420
- ZNR EP 1100 PRIMER 421
- ZNR EP 1100 422
- ZNR ROADCOAT 423
- ZNR ROADCOAT WB 424
- Interior and exterior facade coating 6 products
- ZNR SATEN MACUN 506
- ZNR SÜPER SİVA 507
- ZNR CEOFIX 2500 508
- ZNR SİVA 509
- CEOFIX 500 510
- POLIDECORE CAM SIVA 514
- Flooring and concrete protection 15 products
- ZNR CURE 100 600
- ZNR CURE 120 601
- ZNR HARDCRETE 602
- ZNR ARMORCRETE 603
- ZNR T100 604
- ZNR T200 605
- ZNR T300 606
- ZNR BASKI BETON YS 607
- ZNR RA 608
- ZNR V 120 609
- ZNR SIGUARD 610
- ZNR SOGUARD 611
- ZNR SL 330 612
- ZNR SL 450 613
- ZNR SAC HF 70 614
- Adhesives and grouts 8 products
- Marine 7 products
- ZNR PRIMER MPU 345 900
- ZNR PRIMER MEP 445 901
- ZNR PUTTY MPU SL30 903
- ZNR PUTTY MPU 25 904
- ZNR MPU 370 905
- ZNR PUTTY M LIGHT 906
- ZNR MPU K 580 907
Application temperature
76 products have an application temperature in their record. The same value is in the technical table on the product page.
For products with a single value, the record has the same lower and upper limit. Check the range in the data sheet.
Questions from the field
The pages of 10 systems hold 38 questions and answers in total. The first question from each system is below.
- Foundation and retaining wall waterproofingCan waterproofing be applied from the negative side?
- Terrace and roof waterproofingIs waterproofing enough without a fall?
- Wet area waterproofingAren’t tiles and grout watertight anyway?
- Concrete repair and strengtheningCan mortar be applied without cleaning the reinforcement?
- Car park floor coatingCan the primer be applied without measuring surface moisture?
- Decorative flooringWhen is the hardener broadcast?
- Facade thermal insulation, external insulationShould the adhesive be spread over the whole board?
- Tile fixing and groutingIs the trowel notch chosen according to tile size?
- Wooden and fiberglass boat coating (Draft)Why does a polyurethane topcoat go over the epoxy primer?
- Primer selection (Draft)What happens if the primer is skipped?
Note: Application videos are not published yet.
For a problem on site, call the technical support team. They come to your site for application details.
Data sheets and technical support
The document centre holds the PDF data sheets of 111 products. For questions about your project, you can reach the technical support team Monday–Friday, 08:30–17:30.